Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Usage: | Mobile Phone, Digital Camera, Phone |
| Output Type: | DC |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model Specification |
S-35-5 | S-35-12 | S-35-15 | S-35-24 |
| DC output voltage | 5V | 12V | 15V | 24V |
| Output voltage error(Note2) | ±2% | ±1% | ±1% | ±1% |
| Rated output current | 7A | 3A | 2.4A | 1.5A |
| Output current range | 0-7A | 0-3A | 0-2.4A | 0-1.5A |
| Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
| DC output power | 35W | 36W | 36W | 36W |
| Efficiency | 70% | 76% | 78% | 78% |
| Adjustable range for DC voltage | ±10,-5% | ±10% | ±10% | ±10% |
| AC input voltage range | 85132VAC/170264VACselected by switch | |||
| Input current | 0.85A/115V 0.45A/230V | |||
| AC impulse current | Cold-start current 18A/115V 36A/230V | |||
| Leakage current | <0.5mA/240VAC | |||
| Overload protection | 105%150% Type: current limiting; Reset: auto recovery | |||
| Over-voltage protection | ||||
| High-temperature protection | ||||
| Temperature coefficient | ±0.03%(050) | |||
| Setup rise hold up time | 200ms,100ms,30ms | |||
| Vibration | 10500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||
| Withstand voltage | Input and output intermal:1.5KVAC,Input and enclosute:1.5KVAC,Output and enclosure:0.5KVAC | |||
| Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms | |||
| Working temperature and humidity | -10+60,20%90%RH | |||
| Store temperature and humidity | -20+85,10%95RH | |||
| Overall dimension | 129*98*38mm | |||
| Weight | 0.4Kgs | |||
| Safety standards | Meet UL 1012 requirement(Not apply for the mark) | |||
| EMC standards | Meet FCC Part 15J Conduction Class B | |||
| Note: | ||||